Blastertank - Wastewater purification system equipped with Aquablaster

Next-generation purification system solves
all your wastewater treatment worries!

Blastertank - Wastewater purification system equipped with Aquablaster FY2005 Kansai Bureau of Economy, Trade and Industry NBK Grand Prize Prize in the Environment and Amenities category

Now even more powerful with 100% aerobic respiration and powerful convections stirring plus biological carrier agent!

Equipped with Aquablaster

Outstanding features of Aquablaster

  • Highly efficient oxygen- dissolution efficiency
  • Airlift effect sweeps up sludge from bottom
  • Outstanding performance even with high-load wastewater
  • Ideal for livestock wastewater as well
  • Maintenance free
  • Greatly improved durability
Water film type Scrubber Deoriser

What's the secret behind superior water treatment?

By facilitating 100% aerobic-respiration metabolism of microorganisms, Aquablaster maximizes biological breakdown capacity.

In biology terms, this is a very simple process, but there are astonishingly few apparatuses and pieces of equipment that capitalize on this phenomenon.

An unpleasant odor indicates that microorganisms' metabolism is weak.

*This is a very simple mechanism from a biology standpoint,
but for some reason, there is no other equipment on the market that applies it.

[Unpleasant odors and treatment mechanisms]

1. Aerobic respiration

1. Aerobic respiration

When organic material enters the water, microorganisms begin to biodegrade itforcefully. In this process, however, they consume large amounts of oxygen.

Water treatment effective

2. Anaerobic respiration

2. Anaerobic respiration

When oxygen is rapidly consumed, the environment becomes bereft of oxygen and respiration of other substances such as sulfur ions begins. This is known as "anaerobic respiration," which generates byproducts such as hydrogen sulfide.

Water treatment ineffective

3. Anaerobic fermentation

3. Anaerobic fermentation

When sulfur ions start to be consumed as well, the process turns to "anaerobic fermentation" and putrefactive gases such as acetic acid, butyric acid, and propionic acid gas are generated.

Water treatment ineffective

4. Aerobic respiration

4. Aerobic respiration

Aquablaster facilitates the aerobic respiration of microorganisms for efficient water treatment without putrefaction.

Water treatment effective

Poor metabolic efficiency indicates that effective water treatment is not taking place.

*Aience 100% guarantees no foul odors are generated (at Aience design stage)

Outstanding performance, unthinkable with conventional water purification systems.

Aquablaster facilitates 100% aerobic respiration and powerful vertical stirring inside the tank, producing the following effects.

  1. Maximizes the degradation capacity of microorganisms, for extremely powerful breakdown of oil and other substances. (Maximum metabolism = One unit of glucose → 38 units of ATP generated)
  2. Absolutely no generation of foul odors from hydrogen sulfide, etc.
  3. When discharging to sewer systems, no activated sludge is used, only suspended solids below the acceptable discharge limit. No need for sludge treatment (some exceptions may apply depending on the type of wastewater).
  4. Aquablaster sweeps up water from bottom for minimal sludge accumulation
Preliminary tests are conducted on site at your facility, determining the length of time required for treatment, and preliminary investigation (no costs borne by customer except for measuring expenses), so you can use our product with confidence.
Preliminary verification and a 15-year track record have given us a 100% success rate.
We 100% guarantee odor-free wastewater!

Used effectively at all sorts of treatment facilities.

use1
use2
use3
use4

Blaster Tank meets a wide range of needs

1. Users who want to release wastewater to sewer system with no sludge (only suspended solids within acceptable discharge limit).Extensive track record in this area
2. Users who want to eliminate pressurized flotation unit, reduce maintenance work and scale down use of condensing agents.
3. Users requiring backup because existing treatment equipment has reached capacity.
4. Users who want to install additional water treatment tanks but have no place to install them, or other users with concerns should feel free to consult Aience.

Please conduct a thorough preliminary study when dealing with wastewater thought difficult to handle with biotreatment.

1. COD-overloaded wastewater (where BOD: COD ration exceeds 1:2)
2. Inorganic wastewater (treatment can be applied to prevent unpleas- ant odor generation and boost condensing power)

Application examples

Pre-treatment replacing pressurized flotation unit

Pre-treatment replacing pressurized flotation unit

Pre-treatment of high-load wastewater

Pre-treatment of high-load wastewater

Post-treatment when water treatment has been ineffective

Post-treatment when water treatment has been ineffective

Treatment of wastewater containing mineral oils

Treatment of wastewater containing mineral oils

Blaster tank standard specifications

Detailed diagram
If you are unable to install the system aboveground, we also offer underground installation. Please inquire for details.

If you are unable to install the system aboveground, we also offer underground installation. Please inquire for details.

Specification table

 BT-5BBT-10BBT-20BBT-30BBT-40BBT-50B
Tank capacity(m³)51020304050
Air blower Output(kw)3.75.511.011.015.018.5
Tank materialSUS304, SS400, Polyethylene, FRP
Tank diameter(mm)1,8002,0002,4003,0003,0003,200
Tank height(mm)2,0003,2004,5004,3005,7006,750
Number of Aquablaster units446678
  • BT-5B, 10B are equipped only with a simple ladder. 
  • BT-20B, 30B, 40B, 50B are equipped with ladder with protective rail, and safety fence all around perimeter. 
  • Dimensions are listed for reference only. 
  • Please be aware that designs may be modified as needed.
plastic drum

Plastic-drum test models are available for borrowing. Try it for yourself on-site and see the effects.

Related Products

Aquablaster diffusion pipe
Diffusion pipe responding to wastewater treatment in various fields that has revolutionized the concept of water treatment.
Blastertank
Wastewater purification tank equipped with Aquablaster.
AIS Transform System
The AIS Transform System is so revolutionary that the roles and arrangements of tanks can be changed freely to suit your needs.

For any question about wastewater, circulating water, and exhaust gas treatment, feel free to contact us.

For an inquiry by email.